BRILLIANT PROBE
This technology is aimed at extending the product life cycle. By applying DS Testics’s independent technology to the plunger that comes into contact with a device, pollution caused by Sn transition is suppressed and, as a result, the product life time is extended and the cleaning time is reduced.
| sortation | Product Specifications | |
|---|---|---|
| Spring Force | Initial Force | 5.2gf |
| Recommended Stroke | 35.0gf @ 0.48mm | |
| Full Stroke | 42.4gf @ 0.60mm | |
| MaTerial Spec. | Barrel | Phosphor Bronze Tube (Au Plated) |
| Top Plunger | N1 (G1) | |
| Bottom Plunger | Hardened BeCu (Au Plated) | |
| Spring | Stainless Steel Wire (Au Plated) | |
| Mecahnical Spec. | Pointing Accuracy | ±0.050mm |
| Operating Temperature | -55 to +150˚C | |
| Spring Life Expectancy | 250k Cycle | |
| Electrical Spec. | DC Resistance (Avg.) | Less Than 60mΩ |
| Current Rating | 2.0 A Continuous (Reference) | |
| Band Width | TBD (To Be Determined) | |
| Self Inductance | ||
| Capacitance | ||